Guangzhou Huadu Guang Er Zhong Electronic Factory
Main products:Switching Power Adapter,power adapter
Products
Contact Us
  • Contact Person : Mr. Tan John
  • Company Name : Guangzhou Huadu Guang Er Zhong Electronic Factory
  • Tel : 86-020-86944192
  • Fax : 86-020-86944872
  • Address : Guangdong,GUANGZHOU,(EAST OF HUASHAN TOWN GOVERNMENT)DONG HUA INDUSTRIAL HUASHAN TOWN HUADU DISTRICT GUANGZHOU CITY
  • Country/Region : China
  • Zip : 510880

switching mode power supply

switching mode power supply
Product Detailed
switching mode power supply Input voltage 100V-240V AC Efficiency 95% Certificate: UL

switching mode power supply  

1 Product characteristics

Input: 100-240V 50/60HZ(47/63HZ)

Output power:12W

Output voltage:3-24V

Output current:0.1-2A

Line regulation: ±1%

Load rang: ±5%

Dielectric Strength test: AC 3000V /5MA

Insulation resistance: DC 500V /100MΩ

Energy efficiency Level 5 Energy Star (V 2.0)

Size: 97*45*35(mm)

2 Safety compliance standards

CUL,UL (ITE UL60950 )TUV/GS(ITE EN60950 )CE, CB,VDE,UL,FCC,CCC(ITE GB4943)SAA,PSE,KC

3 Output characteristic:

3.1 Static Output Characteristics<VO & R+N

R+N: 120mVP-P

Ripple & Noise: Measurement is done by 20MHz bandwidth oscilloscope and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolysis capacitor.

Test under the condition of rated input and rated output

3.2 Turn-on Delay Time: 3S max. 100Vac to 240 Vac input & Full load/

3.3 Hold-up Time: 20mS min. Full load & 230Vac/50Hz input turn off at worst case

3.4 Rise Time: 20mS max. Rated load

3.5 Fall Time: 60mS max.Full load

3.6 Output Overshoot/Undershoot: 10% max. When the power on or off

4 Reliability Average fault-free times under 25°C ambient temperature maximum working loadAverage fault-free time 50000 hours (As per MIL-HDBK-217 Standards)

5 Environmental requirementsWorking temperature 0°C - 40°C maximum working loadStorage temperature -20°C - 60°CMoisture under non-condensing condition, moisture 5% - 95%

6 Tests:

Burn-in test: power supply shall be burn-in for 4 hours under normal input and 80-100% rated load at 40°C±5°C

Height: 1m,the product should be fall off on the hardwood with the thickness of 20mm,and the hardwood shall be put on the base of the cement or on the ground without flexibility. Apply two times on all surface.

6.1 Dielectric Strength (Hi-pot):

Primary to Secondary: 3000Vac/5mAMax/3second

6.2 Leakage Current: 0.2mAmax.at 264Vac/50Hz

6.3 Insulation Resistance: 50M min. at primary to secondary add 500Vdc test voltage

7 MTBF Qualifications:

The MTBF shall be at least 50,000 hours at 25°C, Full load and input condition (As per MIL-HDBK-217 Standards)

8 Protections:

Short Circuit Protection: The input power shall decrease when the output rail short, the power supply shall not damage, and shall be self-recovery when the fault condition is removed.

Output protection

Overvoltage protection: 120%MIN

Over current protection: 120%MIN

switching mode power supply



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.